Get complete information related to latest Rotary Drum Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rotary Drum Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rotary Drum Tenders.
Tender For corrigendum : design, supply, installation, commissioning and testing of substation pressurization system for c2c3 substation, lpg1 substation, lpg 2 substation, nbph substation, 11kv/22kv swgr compartment of cogen substation at ongc uran
Tender For corrigendum : supply installation testing and commissioning of sprinkler smoke extraction and pressurization system at shakti bhawan building lucknow
Tender For supply of supply of (e&m) item-, supplying of one number 3.5c x 300 sq.mm pvc insulated and pvc sheathed/xipe al. armoured conductor power cable of 1.1 kv grade of following ways complete etc as reqd., supplyof 2 kg hfc 227 ca/fk-5-1-12 with 10 mtr minimum heat sensing tube fire suppression system. clean agent hfc 227 ca/fk-5-1-12 dlp (direct low pressure) with zero ozone depletion potential. container along with valve assembly: clean agent hfc 227 ca/fk-5-1-12 direct complete as reqd operating pressure is 15 bar at 20 degree. sensor tube automatic fire suppression system, made by special modified polyamide double layered color blue/black/red, high grade hr quality, stabilized, inner diameter 4mm.outer diameter 6mm, sensor tubing hr blue/black/red in mtr. senso tube uv resistance with pressurization of tube using nitrogen gas. the hst conductive, non-corrosive and flexible. operating pressure: 15 bar end of line plug-maximum working pressure 20 bar. t connections., pressure switch. pressure valve - direct low pressure type with inbuilt pressure gauge, integrated ball valve for open/ close within the valve body. reed switch to monitor the valve position using the reed switch relay to indicate valve open/close position. power back up for monitoring panel- 12v, 7.2 ah smf batteries (2 nos) end line adopter. 2x1.5 sq. mm pvc insulated pvc seethed copper conductor single core cable wire in meter. required compelete system certification that is equivalent to lpcb standard equivalent to lps 1666: issue 1.0 with indian nabl. lab report., supply of low pressure is 16018 45 itr trolley mounted water mist & caf fire extinguisher with following specifications: water mist & caf fire extinguisher having fire rating 204, 2338 and dielectric test on is: 16018: 2012 (c1.6.8) 36kv at 1 meter distance, with standard afff 3% compound, confirming to is 4989. extinguishing gun stainless steel 1-2 kg approx weight with nabl test report. dual nozzle jet mode to spray mode by twisting of nozzle. suitable for all classes of fire a. b and e. pressure vessel with 45 liter nilling capacity. compressed air cylinder 6 liter 300 bar cylinder which can be inounted on universal air cylinder holder capable of holding these cylinders, length of hose 5 meter, the cylinder should be of red color with powder coating as per is standards the paint should confirm to is: 5:2007 shade 538., cylinders. lancing distance of gun 3-15 meter, flow rate 42 to 50 liter per second. system test: tested from nabl lab/erda, 1) content-water, foam, 2) gun mode jet and spray., supply & foxing of 100 watt led highway light suitable for 120 to 300v of cct(k) $700 lumen efficacy >130, cri minimum 70, mech, impact protection code above ik.08 having pic housing luminaire for enhanced uniform illumination and with ip66/65 protection i/c connection ete complete as reqd.,
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens
Tender For provision of security door lift pressurization and security door engineering of staircase and lobby at dhh dhenkanal for compliance of shortfall of alsbm system